CP-Parameterdenition
The conguration parameters are inserted in the Ud.group and indirect addressed like the conguration para-
meters of the CP parameters over a selector.
The following parameters result from it:
Ud.22: PP parameter selection Value range: 0...47
Ud.23: PP address
Value range: -1(off)..7FFFH, only available and permitted
addresses are acepted
Ud.24: PP feature Value range: 1...1023
Ud.25: PP multiplier/ write Value range: +/- 32767
Ud.26: PP shifter/ write Value range: 0..48
Ud.27: PP multiplier/ reading Value range: +/- 32767
Ud.28: PP shifter/ reading Value range: 0..48
Ud.29: PP offset Value range: +/- 2^31 -1
Ud.30: PP upper limit Value range: +/- 2^31 -1
Ud.31: PP lower limit Value range: +/- 2^31 -1
Example
Reading of the prog. parameters
The values of the source parameter in the selected sets are compared. If all values are equal then this value
is displayed, otherwise „data invalid“ is displayed. If no source parameter is dened, „data invalid“ is displayed.
Writing of the prog. parameters
The write value is written into all selected sets of the target parameter.
The following characteristics of the target parameter are checked:
Exceeding the limits: „invalid data“
Generally write protection: „write protected parameters“
Wwrite protection at switch on modulation: „operation not possible“
Write protection in the active set: „invalid set“
Password: ‘Password invalid‘ is only displayed at parameters with supervisor-password
„Data invalid“ is always displayed if no source parameter is dened.
Invalid target/source parameters
Some parameters cannot be adjusted as target/source parameter in ud.23. This means all parameters, which
are not permissible as CP-Parameters (characteristics 2 bits 15 = 1) or process date (characteristics 1 bit 28 =
1), as well as the prog. parameters. Explanation:
- all sy parameters exception sy.02, 06, 07, 32, 41-44, 50-53
- uf.12-14
- all ud parameters exception ud.01, 09
- fr.01
- In.20,21,31-33
- Ec.00,10,36-38
- AA.00-13, 26-29, 34-41
- PP.00-47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5-A and is the answer not in the manual?

KEB COMBIVERT F5-A Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5-A
CategoryControl Unit
LanguageEnglish

Related product manuals