Page #66 background imageLoading...
Page #66 background image
Page 6.2 - 16 COMBIVERT F5-A, -E, -H © KEB, 2012-10
Start-up
6.2.2.1 Start-up F5A-S
Steps 1 to 10 can be skiped when using a system consisting of KEB COMBIVERT F5 and KEB servo motor.
The unit is already preset by a specic motor download.
The following steps describe a standard start-up when using a "customer-specic motor“. Enocer interface 1 is
used as encoder feedback.
1. Open control release
deactivate terminal X2A.16
ru.00 inverter state = nop/ „no control release“
2. Selection of the speed range
The usable speed range is adjusted with Ud.02:
Ud.02 control type = 8…11
All data for the adjustment of the controller
type (e.g. resolution of the speed, etc.) see
chapter 5.1
3. Loading the default parameters
Loading the default parameters (KEB factory setting) by
Fr.01 copy parameter set = - 4
Attention:
Pre-adjustments (e.g. function of the digital
inputs) disappear
4. Select source of the speed feedback
cS.01 actual source = 0: Channel 1
5. Enter increments per revolution of the speed feedback
Ec.01 encoder 1 (inc/r) Note:
Not valid for resolver