Troubleshooting
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 8.1 - 9
8
Display COMBIVIS Value Meaning
A.PrF
Warning ! prot. rot. for. 94
The drive has driven onto the right limit switch. The response to this
warning can be programmed.
A.Prr
Warning ! prot. rot. rev. 95
The drive has driven onto the left limit switch. The response to this
warning can be programmed.
A.SbuS
Warning ! Bus synchron 103
Sychronization over sercos-bus not possible. The response to this
warning can be programmed.
A.SEt
Warning ! set 102
It has been attempted to select a locked parameter set. The response
to this warning can be programmed.
A.SLF
Warning ! Software limit
switch forward
104
The target position lies outside of the limit dened with the right software
limit switch. The response to this warning can be programmed.
A.SLr
Warning ! software limit
switch reverse
105
The target position lies outside of the limit dened with the left software
limit switch. The response to this warning can be programmed.