referring to the following instructions.
Connection of an incorrect power supply may cause fire, electrical shock or damage to the
units.
- Use the specified power supply cable.
Otherwise fire or generation of heat may result.
- Confirm the voltage between the Flang and the minus terminal of the ship’s battery does not
exceed 0.65 volts after the installation completed.
Use the larger diameter cable if the voltage exceeds 0.65 volts.
Otherwise the damage to the Transducer unit due to the electrolytic corrosion may results.
-Turn off the power and hold the plug when connecting or disconnecting the cable.
Otherwise the cable gets damaged and causes electrical shock or fire.
- Do not bent or twist the cables and not to put the heavy obstacles on the cable.
Wiring positions should not disturb the sailing operation or interfere with walking.
It may cause fire, generation of heat or injury.