S748-772 Instructions Manual | 4 Product life cycle handling
4 Product life cycle handling
4.1 Transport
Only by qualified personnel in the manufacturer’s original recyclable packaging
Avoid shocks
Temperature: –25 to +70°C, max. 20K/h rate of change, class 2K3 acc. to EN61800-2,
EN60721-3-1
Humidity: max. 95% relative humidity, no condensation, class 2K3 acc. to EN61800-2,
EN60721-3-1
If the packaging is damaged, check the unit for visible damage. In this case, inform the
shipper and the manufacturer.
The servo amplifiers contain electrostatically sensitive components which can be damaged
by incorrect handling. Discharge yourself before touching the servo amplifier. Avoid contact
with highly insulating materials (artificial fabrics, plastic films etc.). Place the servo amplifier
on a conductive surface.
4.2 Packaging
The S700 packaging consists of recyclable cardboard with inserts.
Dimensions S748/S772: (HxWxD) 390x600x400 mm
Labeling : nameplate outside at the box
4.3 Storage
Storage only in the manufacturer’s original recyclable packaging
Max. stacking height S748...S772: 3 cartons
Storage temperature: -25 to +55°C, max. rate of change 20K/h, class 1K4 acc. to
EN61800-2, EN60721-3-1
Storage humidity: 5 ... 95% relative humidity, no condensation, class 1K3 acc. to
EN61800-2, EN60721-3-1
Storage duration: Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC
for about 30 minutes to the terminals L1 / L2.
4.4 Decommissioning
Only professional staff who are qualified in electrical engineering are allowed to decom-
mission parts of the system.
DANGER: Lethal Voltages!
There is a danger of serious personal injury or death by electrical shock or electrical arcing.
Switch off the main switch of the switchgear cabinet.
Secure the system against restarting.
Block the main switch.
Wait at least 10 minutes after disconnecting.
18 Kollmorgen | kdn.kollmorgen.com | July 2019

Table of Contents

Other manuals for Kollmorgen S70101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen S70101 and is the answer not in the manual?

Kollmorgen S70101 Specifications

General IconGeneral
BrandKollmorgen
ModelS70101
CategoryAmplifier
LanguageEnglish

Related product manuals