4.5 Maintenance and cleaning
The device does not require maintenance. Opening the device voids the warranty. The inside
of the unit can only be cleaned by the manufacturer.
Do not immerse or spray the device. Avoid that liquid enters the device.
To clean the device exterior:
1. Decommission the device (see chapter 4.4 "Decommissioning").
2. Casing: Clean with isopropanol or similar cleaning solution.
Caution : Highly Flammable! Risk of injury by explosion and fire.
Observe the safety notes given on the cleaning liquid package.
Wait at least 30 minutes after cleaning before putting the device back into operation.
3. Protective grill on fan: Clean with a dry brush.
4.6 Disassembly
Only professional staff who are qualified in electrical engineering are allowed to disassemble
parts of the system.
1. Decommission the device (see chapter 4.4 "Decommissioning").
2. Check temperature.
CAUTION: High Temperature! Risk of minor burns. During operation, the heat sink of
the drive may reach temperatures above 80°C (176°F). Before touching the device,
check the temperature and wait until it has cooled below 40°C (104°F).
3. Remove the connectors. Disconnect the potential earth connection last.
4. Demount: loosen the fastening screws. Remove the device.
S748-772 Instructions Manual | 4 Product life cycle handling
Kollmorgen | kdn.kollmorgen.com | July 2019 19

Table of Contents

Other manuals for Kollmorgen S70101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen S70101 and is the answer not in the manual?

Kollmorgen S70101 Specifications

General IconGeneral
BrandKollmorgen
ModelS70101
CategoryAmplifier
LanguageEnglish

Related product manuals