4 Handling
4.1 Transport
l
Only by qualified personnel in the manufacturer’s original recyclable packaging
l
Avoid shocks
l
Temperature –25 to +70°C (-13...158°F), max. 20K/hr rate of change
l
Humidity max. 95% relative humidity, no condensation
l
The servo amplifiers contain electrostatically sensitive components which can be
damaged by incorrect handling. Discharge yourself before touching the servo ampli
-
fier. Avoid contact with highly insulating materials (artificial fabrics, plastic films etc.).
Place the servo amplifier on a conductive surface.
l
If the packaging is damaged, check the unit for visible damage. In this case, inform the ship
-
per and the manufacturer.
4.2 Packaging
l
Cardboard box, can be recycled
l
Dimensions: (HxWxD) 410x470x490 mm
l
Weight incl. accessories approx. ca. 25 Kg
l
Labeling : nameplate outside at the box
4.3 Storage
l
Storage only in the manufacturer’s original recyclable packaging
l
Max. stacking height 3 cartons
l
Storage temperature -25 to +55°C, max. rate of change 20°C / hour
l
Storage humidity 5 ... 95% relative humidity, no condensation
l
Storage duration Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC for
about 30 minutes to the terminals L1 / L2.
4.4 Maintenance
The instruments do not require any maintenance, opening the instruments invalidates the warranty.
Cleaning : — if the casing is dirty: clean with Isopropanol or similar
do not immerse or spray
— if there is dirt inside the unit it must be cleaned by the manufacturer
— dirty protective grill on fan must be cleaned with a dry brush
SERVOSTAR
®
640/670 Instructions Manual 15
Kollmorgen
12/2010 Handling