9.3.7 Save Parameters and Restart
You are going to finish setup and you have changed several basic parameters. Depending on the
parameters you changed, two possible reactions can occur:
Configuration parameters changed
A warning appears, that you have to restart the amplifier. This is called "coldstart". Click "YES". The
parameters are saved to the amplifier's EEPROM automatically and a reset command restarts the
amplifier (takes a few seconds). For example, this happens after motor or feedback selection.
Other parameters changed
No warning appears. Parameters are saved in the volatile RAM only. Save the parameters to the
EEPROM of the servo amplifier manually by clicking the symbol in the tool bar. A coldstart
of the amplifier is not necessary.
Reset the amplifier
You can reset the amplifier manually (e.g. in case of an error). Click the icon .