MX’er SYSTEM
and then the positive (+) cable.
The installation sequence is the reverse of
removal.
BATTERY VOLTAGE (OPEN CIRCUIT
VOLTAGE) INSPECTION
Remove the seat.
Disconnect the battery cables.
Measure the voltage between the battery
terminals.
Fully charged : 13.1V
Undercharged : 12.3V max
CHARGING
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
Charging current : Standard : 0.9A
Quick : 3.0A
Charging time : Standard : 5 10 hours
Quick : 30 minutes
After charging: Open circuit voltage: 12.8V min.
CHARGING SYSTEM
SHORT CIRCUIT TEST
Disconnect the ground wire from the battery
and connect an ammeter across the battery
negative (-) terminal and the ground wire.
the battery to avoid explosion.
• Charge the battery according to the current
specified on the battery.