14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14
-
4
MXer SYSTEM
and then the positive (+) cable.
The installation sequence is the reverse of
removal.
BATTERY VOLTAGE (OPEN CIRCUIT
VOLTAGE) INSPECTION
Remove the seat.
Disconnect the battery cables.
Measure the voltage between the battery
terminals.
Fully charged : 13.1V
Undercharged : 12.3V max
CHARGING
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
Charging current : Standard : 0.9A
Quick : 3.0A
Charging time : Standard : 5 10 hours
Quick : 30 minutes
After charging: Open circuit voltage: 12.8V min.
CHARGING SYSTEM
SHORT CIRCUIT TEST
Disconnect the ground wire from the battery
and connect an ammeter across the battery
negative (-) terminal and the ground wire.
Lock Lever
Keep flames and sparks away from a
charging battery.
Turn power ON/OFF at the charger, not at
the battery terminals to prevent sparks near
the battery to avoid explosion.
Charge the battery according to the current
specified on the battery.
Quick charging should only be done in an
emergency.
Measure the voltage 30 minutes after the
battery is charged.
*
Battery charging inspection must be
performed with a voltmeter.
*
First connect the positive (+) cable and then
negative (-) cable to avoid short circuit.