15. IGNITION SYSTEM
15
-
4
MXer SYSTEM
Testing Range
Use the xK range for the Sanwa Tester.
Use the xK range for the Kowa Tester.
Note: The readings in this table are taken with a
Sanwa Tester.
Unit: K
Test the CDI unit using the CDI tester.
Connect the special connector to the CDI
coupler and CDI tester.
Black/
White
Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper tester
in an improper range may give false
readings.
Use a Sanwa Electric Tester or Kowa
Electric Tester.
In this table, “Needle swings then returns”
indicates that there is a charging current
applied to a condenser. The needle will
then remain at “ ” unless the condenser is
discharged.
*
Blue/Yellow
CDI Unit
Black
/Red
Black
/Yellow
Green/White
Green/Red
Probe
(-)Probe
Black/
White
Black/
Red
Blue/
White
Green
Green/
White
Black/
Yellow
Black/
White
Black/
Red
3-6K
Blue/
White
35-42K 18-22K 8-10K 8-10K
Green
15-18K 4.5-5.5K
7-9K
There is
continuity
Green/
White
15-18K 4.5-5.5K
8-9K
There is
continuity
Black/
Yellow
Needle
Swings then
Needle
Swings then
Change Gear Control
Operate the CDI tester by following
the
manufacturer‘s instructions.
*