(4) Firmware Environment Commands
The printer maintains a number of printing parameters in its memory. There parameters may be changed per-
manently with the FRPO (Firmware RePrOgram) commands.
This section provides information on how to use the FRPO command and its parameters using examples.
Using FRPO Commands for Reprogramming Firmware
The current settings of the FRPO parameters are listed as optional values on the service status page.
Note: Before changing any FRPO parameter, print out a service status page, so you will know the parameter
values before the changes are made. To return FRPO parameters to their factory default values, send the
FRPO INIT (FRPO-INITialize) command.(!R! FRPO INIT; EXIT;)
The FRPO command is sent to the printer in the following sequence:
!R! FRPO parameter, value; EXIT;
Example: Changing emulation mode to PC-PR201/65A
!R! FRPO P1, 11; EXIT;
FRPO Parameters
Environment Param
eter
Values Factory
setting
Top margin A1
A2
Integer value in inches
Fraction value in 1/100 inches
0
0
Left margin A3
A4
Integer value in inches
Fraction value in 1/100 inches
0
0
Page length A5
A6
Integer value in inches
Fraction value in 1/100 inches
16
61
Page width A7
A8
Integer value in inches
Fraction value in 1/100 inches
16
61
Default pattern resolution B8 0: 300 dpi
1: 600 dpi
0
Page orientation C1 0: Portrait
1: Landscape
0
Default font No. * C2
C3
C5
Middle two digits of power-up font
Last two digits of power-up font
First two digits of power-up font
0
0
0
PCL font switch C8 0:HP compatibility mode (Characters higher
than 127 are not printed.)
32:Conventional mode (Characters higher than
127 are printed. Supported symbol sets: ISO-60
Norway [00D], ISO-15 Italian [00I], ISO-11 Swe-
den [00S], ISO-6 ASCII [00U], ISO-4 U.K.
[01E], ISO-69 France [01F], ISO-21 Germany
[01G], ISO-17 Spain [02S], Symbol [19M]
a
)
* : Characters higher than 127 are printed
regardless of the C8 value. However,
setting C8 to 0 does not print character
code 160.
0