8: Device Ports
SLC™ Console Manager User Guide 135
3. Click the Add Site button.
To view or update a site:
1. In the Sites table, select the site and click the View Site button. The site attributes are
displayed in the bottom half of the page.
2. Update any of the site attributes.
3. Click the Edit Site button.
To delete a site:
1. Select the site in the Sites table.
2. Click the Delete Site button.
Configures a set of site-oriented modem parameters that can be activated by various modem-
related events (authentication, outbound network traffic for DOD connections, etc.).
The site parameters will override any parameters configuredfor the modem.
Uses sites with a modem, enable 'usesites'. Sites can be used with the following modem states:
dialin, dialback, cbcpserver, dialondemand, dialin+ondemand, and dialback+ondemand.
To create or edit a site:
set site add|edit <Site Name> [<parameters>]
Parameters:
name <Site Name> (edit only) dialoutnumber <Phone Number>
deviceport <Device Port # or Name or none> dialoutlogin <User Login>
usbport <U1|U2> dialoutpassword <Password>
pccardslot <upper|lower> allowdialback <enable|disable>
auth <pap|chap> dialbacknumber <Phone Number>
loginhost <User Login/CHAP Host> dialbackdelay <Dial-back Delay>
chapsecret <CHAP Secret> dialbackretries <1-10>
localipaddr <negotiate|IP Address> timeoutlogins <disable|1-30
minutes>
remoteipaddr <negotiate|IP Address> modemtimeout <disable|1-9999 secs>
route ipaddr <I P Address> routem ask <Mask >
restartdelay <PPP Restart Delay> cbcpnocallback <enable|disable>
routegateway <Gateway> nat <enable|disable>
To delete a site:
set site delete <Site Name>
show site <all|names|Site Name>
Restart Delay The number of seconds after the modem timeout and before the SLC console
manager attempts another connection. The default is 30 seconds.
CBCP Server
Allow No Callback
For a CBCP Server site, allows "No Callback" as an option in the CBCP
handshake in addition to User-defined Number and Admin-defined Number.
Enable NAT Select to enable Network Address Translation (NAT) for PPP connections.
Note: IP forwarding must be enabled on the Network - Settings page for NAT to
work.

Table of Contents

Other manuals for Lantronix SLC8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC8 and is the answer not in the manual?

Lantronix SLC8 Specifications

General IconGeneral
BrandLantronix
ModelSLC8
CategoryServer
LanguageEnglish

Related product manuals