5555
LeeBoy 8520C Conveyor Paver 5-27
Maintenance
Battery ServicingBattery Servicing
1. Open the access panel on the right side of the
operator station to access battery.
NOTE: If replacing the battery, discard the old
battery properly.
2. Before connecting the batteries, turn off the master
switch, located just above the battery. (Figure
5-29)
Master
Battery
Switch
Battery
Figure 5-29. Battery and Master Switch
3. Be certain that battery terminals and posts are clean
and that the battery cable terminals are tight.
Dirty or loose battery connections can
create high electrical resistance and permit arcing.
4. If corrosion is present around terminal connections,
remove and wash with ammonia or a solution of
1/4-pound baking soda added to one quart of warm
water. Ensure the vent caps are tight to prevent
solution from entering the cells.
5. Pour clean water over the battery and surrounding
area to rinse away the solution.
6. Check vent cap breather openings to ensure they
are clear.
AlternatorAlternator
The alternator supplies electrical power to electronic
controls and charges the battery. Its built-in regulator
controls voltage output. (Figure 5-30)
Figure 5-30. Alternator
Use the following precautions to prevent damage to the
alternator or regulator:
• Never polarize the alternator.
• Never ground any alternator terminals or circuits.
• Always disconnect the battery before disconnecting
or connecting the alternator.
• Never disconnect the alternator while machine is
operating.
• Ensure wiring is properly connected before
connecting the battery.
• Always connect a booster battery in the proper
polarity: Negative (-) to negative (-) and positive (+) to
positive (+).