140
T2
T4
T1
T3
H4652/2
L4652/2 AM5832/2
067552
Basic control for 2 independent loads
2. Automation control
2.1 Addressing
Address type Virtual configuration (MYHOME_Suite) Physical configuration
Point-to-point Room 0-10 A1, A2=1-9
Lighting point 0-15 PL1, PL2=1-9
Room 0-10 A1, A2=AMB, PL1, PL2=1-9
Group 1-255 A1, A2=GR, PL1, PL2=1-9
General general A1, A2=GEN
NOTE:
With the virtual configuration, for the room, group or general controls, you can set a
lighting point address for the return of the load status
Virtual configuration (MYHOME_Suite) Physical configuration
Parameter / setting
Bistable control
M1, M2=
Monostable control
M1, M2=M
Bistable control and lath control M1, M2=6
3. Programmed scenario activation
Virtual configuration (MYHOME_Suite) Physical configuration
Top button 0-31 M1, M2=CEN
Bottom button 0-31 M1, M2=CEN
Virtual configuration (MYHOME_Suite) Physical configuration
Addressing type
Room 0-10 1-9
Lighting point 0-15 1-9
3.1 Addressing
3.2 Mode
NOTE:
If used only for CEN controls (M1=M2=CEN), do not configure A2, PL2.
T1-T4= scenario buttons 1-4
4. Plus programmed scenario activation
To configure address 1 - 2047 of the scenario and number 0 - 31 use MYHOME_Suite
virtual configuration
2.2 Mode
MQ00286-d-EN 20/01/2014