194
L4680
574503
N4680
573902
NT4680
573903
HD4680
067217
HC4680
067218
HS4680
574504
Scenario control
MQ00288-c-EN 09/06/2014
1.1 Addressing
Function Virtual configuration (MYHOME_Suite) Physical configuration
Room (of the scenario module) 0-10 A=0-9
Light point (of the scenario module) 0-15 PL=1-9
Virtual configuration (MYHOME_Suite) Physical configuration
Function Parameter / setting
Scenario modification and activation
Scenario top button 1-16
M=1-4
1)
Scenario bottom button 1-16
1.2 Mode
Function selection
1. Scenario module control
NOTE:
Positions A and PL of the scenario control must correspond to those in the scenario module
item F420. The association of each key of the control to one of the scenarios stored by the module is
made by configuring socket M. It is possible to configure positions N and DEL to set the number of
the scenario to be activated with a delay (from 15s to 15m).
If the device is installed in a My Home system it can be configured in two ways:
- PHYSICAL CONFIGURATION, inserting the configurators in position.
- Configuration via MYHOME_Suite software package, downloadable from
www.homesystems-legrandgroup.com; this mode has the advantage of offering many
more options than the physical configuration.
For a list of the procedures and their meanings, please refer to the instructions in
this sheet and to the "Function Descriptions" help section in the
MYHOME_Suite software package.
When installed in a Lighting Management system, the device can be configured in the
following ways:
- Project&Download, with the Virtual Configurator software you can perform all the
functions listed below:
- double scenario control
- double CEN control
- double PLUS scenario control
- double CEN PLUS control
For more information on the functions see the glossary before the Technical sheets
chapter.
Configuration
1. Lighting Management System
2. My Home system
NOTE 1:
Correspondence between the 4 keys of the control and the scenarios stored in the module
item F420:
Installation and destination level:
The special control can also be used in systems where there are SCS/SCS interfaces (F422).
By installing the control on the BUS of an interface (installation level), you can control one
or more actuators located on the BUS of another interface (destination level).
Function Virtual configuration (MYHOME_Suite) Physical configuration
Destination level Local bus 1-15 I= 1-9
Riser bus riser I=CEN
Complete system entire system I=0
To configure the installation level use MYHOME_Suite virtual configuration.