Group 9 Equipping/maintenance Page 137
Release 3.00 Leibinger-Jet 2 se
! The LEIBINGER- JET 2 is without pressure and must
be disconnected from the
mains supply. Remove mains plug!
Figure 106
! Undo the 2 Allan screws and remove the entire pressure tank if the tube connections
allow this (picture sequence 1).
! Place the collection tub underneath the tank and remove both connections for the
viscosity regulation. The ink will run out. If necessary all hydraulic connections can
be removed.
! Unscrew the 8 continuous
Allan screws that hold the pressure tank together (picture
sequence 2) and remove the lower half of the housing downwards. The membrane
flange must not be loosened!
! Pull off the filter and slide on the new filter (picture sequence 3).
! Clean any possible dirt in the filter housing with thinner. Examine the O-ring for
damage and clean. If necessary replace.
Unscrew only the continuous allan screws!
4
5
1
2
3