Group 9 Equipping/maintenance Page 150
Release 3.00 Leibinger-Jet 2 se
Manner of proceeding:
! Place the LEIBINGER-JET 2 into the operating mode “Nozzle closed” (1) and “Ink
switch on” (2).
! Deactivate the regulation (3) in the menu level <E29> (main menu !
service/test/system parameter ! service/test & diagnostics ! hydraulic test &
parameter).
! Press the button “pressureless” (4) in the menu level <E29> and wait for a while until
the values for the “membrane” and “pressure” (5) moving towards ~“0“.
! The LEIBINGER- JET 2 is now without pressure and must
be disconnected from the
mains supply. Remove mains plug!
! Detach tube connections and connection cable and dismantle suction pump.
! Rinse out suction pump with solvent.
! Assemble pump again, create tube connections and electrical connection.
! As with the initial commissioning the further steps are performed in the empty
condition. Further information can be found in the chapter Start up!
! If the measure is not successful, the working membrane may be damaged and the
suction pump must be replaced.