Figure 49. Removing the bay 3 drive cage
After you finish
1. Install a replacement unit. See
“Install the drive cage (bay 3)” on page 69.
2. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Install the drive cage (bay 3)
Follow instructions in this section to install the bay 3 drive cage.
About this task
S002
CAUTION:
The power-control button on the device and the power switch on the power supply do not turn off the
electrical current supplied to the device. The device also might have more than one power cord. To
remove all electrical current from the device, ensure that all power cords are disconnected from the
power source.
Attention:
• Read
“Installation Guidelines” on page 29 and “Safety inspection checklist” on page 30 to ensure that you
work safely.
• Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
Procedure
Step 1. Make sure the cage bar is installed in the chassis. To install the cage bar, see
“Install the server
cover” on page 137
.
Step 2. (Optional) Install the EMI shield included in the component packaging to the chassis.
Chapter 5. Hardware replacement procedures 69