11 Appendix
11.1 Table of attributes
324
Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x3404 Motor: Lss saturation characteristic - inductance grid points (y)
1: Lss: y1 = L01 (x = 0.00 %) UNSIGNED_16 - P
2: Lss: y2 = L02 (x = 6.25 %) UNSIGNED_16 - P
3: Lss: y3 = L03 (x = 12.50 %) UNSIGNED_16 - P
4: Lss: y4 = L04 (x = 18.75 %) UNSIGNED_16 - P
5: Lss: y5 = L05 (x = 25.00 %) UNSIGNED_16 - P
6: Lss: y6 = L06 (x = 31.25 %) UNSIGNED_16 - P
7: Lss: y7 = L07 (x = 37.50 %) UNSIGNED_16 - P
8: Lss: y8 = L08 (x = 42.75 %) UNSIGNED_16 - P
9: Lss: y9 = L09 (x = 50.00 %) UNSIGNED_16 - P
10: Lss: y10 = L10 (x = 56.25 %) UNSIGNED_16 - P
11: Lss: y11 = L11 (x = 62.50 %) UNSIGNED_16 - P
12: Lss: y12 = L12 (x = 68.75 %) UNSIGNED_16 - P
13: Lss: y13 = L13 (x = 75.00 %) UNSIGNED_16 - P
14: Lss: y14 = L14 (x = 81.25 %) UNSIGNED_16 - P
15: Lss: y15 = L15 (x = 87.50 %) UNSIGNED_16 - P
16: Lss: y16 = L16 (x = 93.25 %) UNSIGNED_16 - P
17: Lss: y17 = L17 (x = 100.00 %) UNSIGNED_16 - P
18: Motor: Lss saturation characteristic -
activation
UNSIGNED_16 - P
0x3405
Motor: Lss saturation charcteristic - reference for
current grid points (x)
UNSIGNED_16 1/10 P
0x3406
Motor (SM): Magnet characteristic (current) - grid points
1: Magnet characteristic: x1 = i01/iN UNSIGNED_16 - P
2: Magnet characteristic: y1 = kT01/kTN UNSIGNED_16 - P
3: Magnet characteristic: x2 = i02/iN UNSIGNED_16 - P
4: Magnet characteristic: y2 = kT02/kTN UNSIGNED_16 - P
5: Magnet characteristic: x3 = i03/iN UNSIGNED_16 - P
6: Magnet characteristic: y3 = kT03/kTN UNSIGNED_16 - P
7: Magnet characteristic: x4 = i04/iN UNSIGNED_16 - P
8: Magnet characteristic: y4 = kT04/kTN UNSIGNED_16 - P
0x3407
Motor (ASM): Lh saturation characteristic - inductance grid points (y)
1: Lh: y1 = L01 (x = 0.00 %) UNSIGNED_16 - P
2: Lh: y2 = L02 (x = 6.25 %) UNSIGNED_16 - P
3: Lh: y3 = L03 (x = 12.50 %) UNSIGNED_16 - P
4: Lh: y4 = L04 (x = 18.75 %) UNSIGNED_16 - P
5: Lh: y5 = L05 (x = 25.00 %) UNSIGNED_16 - P
6: Lh: y6 = L06 (x = 31.25 %) UNSIGNED_16 - P
7: Lh: y7 = L07 (x = 37.50 %) UNSIGNED_16 - P
8: Lh: y8 = L08 (x = 43.75 %) UNSIGNED_16 - P
9: Lh: y9 = L09 (x = 50.00 %) UNSIGNED_16 - P
10: Lh: y10 = L10 (x = 56.25 %) UNSIGNED_16 - P
11: Lh: y11 = L11 (x = 62.50 %) UNSIGNED_16 - P
12: Lh: y12 = L12 (x = 68.75 %) UNSIGNED_16 - P
13: Lh: y13 = L13 (x = 75.00 %) UNSIGNED_16 - P
14: Lh: y14 = L14 (x = 81.25 %) UNSIGNED_16 - P
15: Lh: y15 = L15 (x = 87.50 %) UNSIGNED_16 - P
16: Lh: y16 = L16 (x = 93.75 %) UNSIGNED_16 - P
17: Lh: y17 = L17 (x = 100.00 %) UNSIGNED_16 - P
0x3408
Motor: Motor parameter setting method UNSIGNED_8 - P