Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 327
11 Appendix
11.1 Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x354C Motor utilisation (I²xt): Parameter for the thermal model
1: Motor utilisation (I²xt): Thermal time constant
- winding
UNSIGNED_16 - P
2: Motor utilisation (I²xt): Thermal time constant
- laminations
UNSIGNED_16 - P
3: Motor utilisation (I²xt): Influence of the
winding
UNSIGNED_8 - P
4: Motor utilisation (I²xt): Starting value UNSIGNED_16 - P
0x354D
Motor utilisation (I²xt): User-definable characteristic
1: I²xt: x1 = n01/nN (n01 ~ 0) UNSIGNED_16 - P
2: I²xt: y1 = i01/iN (x = n01 ~ 0) UNSIGNED_16 - P
3: I²xt: x2 = n02/nN (n02 = limit - reduced
cooling)
UNSIGNED_16 - P
4: I²xt: y2 = i02/iN (x = n02 = limit - reduced
cooling)
UNSIGNED_16 - P
5: I²xt: x3 = n03/nN (n03 = rated speed) UNSIGNED_16 - P
6: I²xt: y3 = i03/iN (x = n03 = rated speed) UNSIGNED_16 - P
7: I²xt: x4 = n04/nN (n04 = limit - field
weakening)
UNSIGNED_16 - P
8: I²xt: y4 = i04/iN (x = n04 = limit - field
weakening)
UNSIGNED_16 - P
0x354E
Motor utilisation (I²xt): Motor overload warning
threshold
UNSIGNED_16 - P
0x354F
Motor utilisation (I²xt): Actual utilisation UNSIGNED_16 - OSC Tx
0x3550 Motor utilisation (I²xt): Motor overload error
1: Motor utilisation (I²xt): Response UNSIGNED_8 - P
2: Motor utilisation (I²xt): Error threshold UNSIGNED_16 - P
0x3551
Monitoring: Position and velocity error
1: Monitoring: Velocity error - error threshold UNSIGNED_32 - P
2: Monitoring: Velocity error - minimum error
time
UNSIGNED_16 - P
3: Monitoring: Velocity error - response UNSIGNED_8 - P
4: Monitoring: Position error - error threshold UNSIGNED_32 - P
5: Monitoring: Position error - minimum error
time
UNSIGNED_16 - P
6: Monitoring: Position error - response UNSIGNED_8 - P
0x3581
Counter: Operating time
1: Device: Operating time UNSIGNED_32 -
2: Device: Power-on time UNSIGNED_32 -
0x3582 Motor: Actual voltage - Veff, phase-phase UNSIGNED_32 1/10 OSC Tx
0x3583 Motor: Phase currents
1: Zero system current INTEGER_32 1/100 OSC Tx
2: Current - phase U INTEGER_32 1/100 OSC Tx
3: Current - phase V INTEGER_32 1/100 OSC Tx
4: Current - phase W INTEGER_32 1/100 OSC Tx
0x3584 Heatsink temperature
1: Heatsink temperature: Actual temperature INTEGER_16 1/10 OSC
2: Heatsink temperature: Warning threshold INTEGER_16 1/10 P
3: Heatsink temperature: Threshold - switch-on
fan
INTEGER_16 1/10 P
4: Heatsink temperature: Threshold - switch-off
fan
INTEGER_16 1/10 P
0x358A
Speed monitoring: Actual speed error INTEGER_32 - OSC Tx
0x35D0 Field: Values
1: Field: Actual field UNSIGNED_16 - OSC Tx
2: Field: Setpoint field UNSIGNED_16 - OSC Tx
Index Name Data type Factor Attributes
Greyed out = read only