0x3463 Pole position identification PPI (without movement)
1: Behaviour after switch-on UNSIGNED_8 - P CINH
Axis B - touch probe
0x3500
Touch probe (TP): Dead time compensation
1: Dead time compensation: TP1 delay time UNSIGNED_16 1/1000 P
2: Dead time compensation: TP2 delay time UNSIGNED_16 1/1000 P
0x3501
Touch probe (TP): Time stamp
1: TP1: Time stamp - rising edge UNSIGNED_32 - OSC Tx
2: TP1: Time stamp - falling edge UNSIGNED_32 - OSC Tx
3: TP2: Time stamp - rising edge UNSIGNED_32 - OSC Tx
4: TP2: Time stamp - falling edge UNSIGNED_32 - OSC Tx
Axis B - monitoring functions
0x3540
Ixt utilisation
1: Power stage utilisation (Ixt): Actual utilisation UNSIGNED_16 - OSC Tx
2: Power stage utilisation (Ixt): Warning
threshold
UNSIGNED_16 - P
3: Power stage utilisation (Ixt): Error threshold UNSIGNED_16 -
4: Device utilisation (Ixt): Actual utilisation UNSIGNED_16 - OSC Tx
5: Device utilisation (Ixt): Warning threshold UNSIGNED_16 - P
6: Device utilisation (Ixt): Error limit UNSIGNED_16 -
0x3544 Motor speed monitoring
1: Motor speed monitoring: Threshold UNSIGNED_16 - P
2: Motor speed monitoring: Response UNSIGNED_8 - P
0x3545
Motor phase failure detection
1: Motor phase failure 1: Response UNSIGNED_8 - P
2: Motor phase failure 1: Current threshold UNSIGNED_8 1/10 P
3: Motor phase failure 1: Voltage threshold UNSIGNED_16 1/10 P
4: Motor phase failure 2: Response UNSIGNED_8 - P
0x3546
Monitoring: Ultimate motor current
1: Ultimate motor current: Threshold UNSIGNED_16 1/10 P
2: Ultimate motor current: Response UNSIGNED_8 - P
0x3549
Motor temperature monitoring: Parameter
1: Motor temperature monitoring: Sensor type UNSIGNED_8 - P
2: Motor temperature monitoring: Response UNSIGNED_8 - P
3: Motor temperature monitoring: Warning
threshold
INTEGER_16 1/10 P
4: Motor temperature monitoring: Error
threshold
INTEGER_16 1/10 P
5: Motor temperature monitoring: Actual motor
temperature
INTEGER_16 1/10 OSC Tx
6: Thermal sensor characteristic: Grid point 1 -
temperature
INTEGER_16 1/10 P
7: Thermal sensor characteristic: Grid point 2 -
temperature
INTEGER_16 1/10 P
8: Thermal sensor characteristic: grid point 1 -
resistance
INTEGER_16 - P
9: Thermal sensor characteristic: grid point 2 -
resistance
INTEGER_16 - P
Index Name Data type Factor Attributes
Greyed out = read only