8400 BaseLine D | Software Manual
Error management
Drive diagnostics with the »Engineer«
122 L Firmware 03.00 - DMS EN 5.0 - 07/2009
If you click the Drive control button, a table appears providing information on the bit
assignment of the following control-relevant words:
– Cause of controller inhibit C158
– Cause of quick stop C159
– Status word C150
– Extended status word C155
Display parameters
The parameters listed in the following tables serve to query current states and actual
values of the controller for diagnostic purposes, e.g. by using the internal keypad, a bus
system or the »Engineer« (with an online connection to the controller).
These parameters are listed in the »Engineer« parameter list and the internal keypad.
A detailed description of these parameters can be found in chapter "Parameter
reference" ( 167).
Identification data
The parameters listed in the following table which are entered in the »Engineer«
parameter list and in the internal keypad in the Identification Controller category, serve
to display the identification data of the controller:
How to diagnose a drive with the »Engineer«:
1. Select the 8400 BaseLine controller to be diagnosed in the Project view.
2. Click the icon or select the command OnlineGo online to build up an online
connection with the controller.
Parameter Display
C051 Actual speed value
C052 Motor voltage
C054 Motor current
C057 Maximum torque
C059 Appl. Nominal frequency C11
C061 Heatsink temperature
C064 Device utilisation (I x t)
C066 Thermal motor load (I
2
xt)
C168 Status-determining error
C178 Elapsed-hour meter
C179 Power-on time meter
Parameter Display
C093 Power section ID
C099,
C100
Firmware version
C200 Firmware product type
C201 Firmware compile date