SHPF ejector jam service check
Action Yes No
Step 1
Make sure that all the optional bins are properly installed.
Does the problem remain?
Go to step 2. The problem is
solved.
Step 2
Clean all the optional bin doors, and then check the paper path
and bins for paper fragments and partially fed paper.
Is the paper path free of paper fragments and partially fed paper?
Go to step 4. Go to step 3.
Step 3
Remove the paper fragments and partially fed paper.
Does the problem remain?
Go to step 4. The problem is
solved.
Step 4
Clear the optional bin paper path rollers of any dirt and
contamination.
Does the problem remain?
Go to step 5. The problem is
solved.
Step 5
a Enter the Diagnostics menu, and then navigate to:
Output bin quick feed > Feed to all bins
b To uc h Single or Continuous.
Does the problem remain?
Go to step 6. The problem is
solved.
Step 6
a Remove the SHPF left cover. See “Staple, hole punch finisher
left cover removal” on page 699.
b Make sure that the controller board of the aected optional bin
is properly installed. Reseat all the cables on the controller
board.
Does the problem remain?
Go to step 7. The problem is
solved.
Step 7
Check the aected controller board and its connector pins for
damage.
Are the bin controller board and its connectors free of damage?
Contact the next
level of support.
Go to step 8.
Step 8
Replace the bin controller board. See
“Staple, hole punch finisher
controller board removal” on page 705.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.