b. Type and enter 2 (for VT100 or ANSI compatible) at the Enter Console
Type: prompt.
Response:
The Main Menu page is displayed.
• If one of the other menu pages is displayed, press the [Esc] key repeatedly
until the Main Menu page is displayed.
25. On the Main Menu page, type and enter 4 for System functions.
Response: The System Commands menu is displayed.
26. Type and enter 6 to Reinitialize.
Response: The Reinitialize page is displayed.
27. Type and enter secret (or the password set for your office) at the Enter Current
Password: prompt.
Response: While the Router is reinitializing, the Router executes power-on self
tests which output status messages onto the Supervisor Console,
and cause the LEDs on the front of the Router to go through a series
of changes. The initial color of the LEDs are yellow/orange, which
turn to red, briefly flash to green, and then completely turn off.
At the conclusion of the power-on self testing, the top row of LEDs
light up on the Router, and the DynaStar Supervisor page is
displayed on the Supervisor Console.
28. After the DynaStar 500 initializes, the unit should be active. If there is no other
problem, the link from the ASM to the DRM should restore. If not, seek
technical support .
29. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
235-200-150
October 2004
NETWORK PROCEDURES
Procedure 3.5
Issue 3.00L Page 3.5-5