6. At Port type,, enter X.25 line. (Use the return key to change.)
Response: The X.25 Port Configuration menu is displayed.
7. At the x.25 Port Configuration Screen, enter the following information: (Use the
arrow keys to navigate the screen)
• At Port name, enter EADAS
• At Connection Mode, enter DCE (Use the return key to change.)
• At Line Speed, enter 64 Kbps (Use the return key to change.)
• At X.25 mode, enter DCE (Use the return key to change.)
• At Max Packet size, enter 256 (Use the return key to change.)
• At IPX Routing, enter N (Use the return key to change.)
• At Ethernet Routing, enter N (Use the return key to change.)
• At Permanent/Number of VCs, enter 3
8. Press the left arrow twice.
Response: The cursor is positioned at Process Selections (Y/N).
9. Enter Y
Response: The Configure Port menu is displayed.
10. To save to flash, Enter <ctrl>w.
11. Press the <Esc> to return to the main menu.
Response: The main menu is displayed.
3.9.3.2 Assign XOT and define the remote IP Address, port and LCN
1. Enter 3 for configuration.
Response: The Configuration Commands menu is displayed.
2. Enter 10 for X.25.
Response: The X.25 Parameters menu is displayed.
3. Enter 5 for XOT switching table.
Response: The XOT PVC SCV Switching Table is displayed.
4. For each of the 7 LCNs, enter the following information: (Use the arrow keys to
navigate the screen)
• At Service, enter PVC/XOT (Use the return key to change.)
• At LOCAL PORT #, enter 204
• At LOCAL LCN #, enter 1, 2, 3, 4, 5, 6,or7
• At REMOTE PORT #, enter the port number for the OS Router that handles
EADAS traffic.
• At REMOTE LCN #, enter 1, 2, 3, 4, 5, 6,or7
• At REMOTE IP Address, enter the IP Address for the OS Router that handles
EADAS traffic.
NETWORK PROCEDURES
Procedure 3.9
235-200-150
January 2003
Page 3.9-2 Issue 3.00