12. Enter the following command to set the system crash dump device to the
secondary disk.
dumpadm -d /dev/dsk/c1t1s0s1
13. Enter luxadm remove_device /dev/rdsk/c1t0s0s2. If the following response is
received, enter c to continue. If this response is not received, seek technical
assistance.
Response:
WARNING!!! Please ensure that no filesystems are mounted on these device(s).
All data on these devices should have been backed up.
The list of devices which will be removed is:
1: Device name: /dev/rdsk/c1t0s0s2
Node WWN: [unique WWN number for the disk unit]
Device Type:Disk device
Device Paths:
/dev/rdsk/c1t0s0s2
Please verify the above list of devices and
then enter ’c’ or CR to Continue or ’q’ to Quit. [Default: c]
14. When prompted with the following response to remove the disk, continue with
step 15. If this response is not received, seek technical assistance.
Response:
stopping: /dev/rdsk/c1t0s0s2....Done
offlining: /dev/rdsk/c1t0s0s2....Done
Hit Return after removing the device(s).
15. Remove the front fascia from the workstation.
16. Locate the LED for the HDD (Hard Disk Drive) on the panel. Refer to Figure
4.5.3-1.
ADMINISTRATIVE WORKSTATION MAINTENANCE
Procedure 4.5.3
235-200-150
October 2005
Page 4.5.3-2 Issue 3.00B