• Customer-supplied Recent Change Verify (RC/V) view for view 8.11 must be
available.
5.11.3 PRECONDITIONING
5.11.3.1 Verify and Set Initial Conditions
1. At the MCC, observe Summary Status Area for a SYS NORM indication.
2. If a SYS NORM indication is not obtained, type and enter: OP:SYSSTAT;
3. At the MCC, type and enter: OP:OFFNORM,SM=a;
Where: a = Switching module number.
Comment: Evaluate system response to determine if system status is
acceptable to continue. Specific attention is required for areas that
can cause an switching module isolation or service impact during
this conversion procedure. Correct any deficiency as required.
Caution: Steps 4 through 6 are recommended but not required. Local
practices should control their use. If routine exercise (REX) is inhibited,
it must be allowed at the conclusion of this conversion procedure.
4. At the MCC, type and enter: INH:REX,SM=a;
Where: a = Switching module number.
Response: OK
5. At the MCC, type and enter: OP:REXINH;
Response: The inhibit status will be printed. Verify this printout.
6. To backup ODD, at the MCC, type and enter: BKUP:ODD,NRODD=a,RODD,AM;
Where: a = Switching module number.
Note: Prior to the response there will be completed responses for the switching
module, and the AM.
Response: BKUP NRODD COMPLETED
Note: Database backup will take several minutes to complete.
5.11.3.2 Turn On Fault Recovery Reports
1. At the MCC, either:
type and enter: SET:PERPH,SM=a,VERBOSE;
or
type and enter: 412 (1800,a CMD)
Where: a = Switching module number.
Response: OK
5.11.3.3 Save Office Message Class Print Options
1. At the MCC, type and enter: CHG:LPS,MSGCLS=ALL,TOBKUP;
Response: OK (with exception)
ROUTINE MAINTENANCE
Procedure 5.11
235-200-150
January 2003
Page 5.11-2 Issue 3.00