Note: The paddle board contains the Ethernet address, verify that the new
board’s DIP switches are set to the same address as the one being replaced. See
Figure 6.6-2 and Table 6.6-1.
Table 6.6-1 Switching Module DIP Switch Settings
MCTSI SWITCH SETTINGS
0 S1=OFF, S2-S8=ON
1 S1=ON, S2=OFF, S3-S8=ON
7. Using the same degree of caution, install the new EI paddle board. Be careful not
to bend the pins or damage the backplane.
8. Connect the coaxial EI bus cable to the new EI paddle board.
9. At the front of the frame, reseat the UN584 circuit pack.
10. At the out-of-service 410AA, power up the MCTSI SG by pressing the ON button.
Response: The OFF lamp is extinguished.
11. Test the new paddle board. At the MCC terminal, type and enter:
DGN:MCTSI=a-b,PH=12,TLP;
Where: a = The switching module number.
b = The MCTSI number (0 or 1).
12. Is the diagnostic response ATP?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE
If NO, continue with Step 13.
13. Warning: The following step will cause an expected loss of
communication between the switching module and the workstation.
Replace the T-connector of the new paddle board.
14. Test the new T-connector. Type and enter the input command used in Step 11.
15. Is the diagnostic response ATP?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE
If NO, continue with Step 16.
16. Warning: The following step will cause an expected loss of
communication between the switching module and the workstation.
Repeat steps 3 and 4, then replace the other T-connector.
17. Test the second new T-connector. Type and enter the input command used in Step
11.
18. Is the diagnostic response ATP?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, continue with Step 19.
19. Warning: The following step will cause an expected loss of
communication between the switching module and the workstation.
235-200-150
January 2003
CORRECTIVE MAINTENANCE
Procedure 6.6
Issue 3.00 Page 6.6-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent 5ESS DRM and is the answer not in the manual?

Lucent 5ESS DRM Specifications

General IconGeneral
BrandLucent
Model5ESS DRM
CategoryControl Unit
LanguageEnglish