19. On the EAI Page, is the INH indicator for Inh Hdw Chk or Inh Sft Chk
backlighted?
If YES, type and enter: 35 and 37
If NO, continue with the next step.
20. On the EAI Page, is the Backup Root indicator SET?
If YES, use ”Recover from BROOT Configuration,” Subprocedure 7.2.4, to recover
root file system, and return to next step.
If NO, continue with next step.
21. Type and enter:
ALW:AUD=SODD,FULL;
22. Reschedule ODD Backup. Type and enter:
BKUP:ODD:EVERY=a,AT=b;
Where: a = Number of days between ODD backups
b = Time of day in hours and minutes (for example 2330 = 11:30
p.m.)
23. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
SYSTEM RECOVERY
Procedure 7.2.1
235-200-150
January 2003
Page 7.2.1-4 Issue 3.00