1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
1234567890123456789012345678901212345678901234567890123456
11. At the RDLDFT display prompt, type and enter: m
Response:
Please enter session number:
12. At the RDLDFT display prompt, type and enter: the session number [1-9] from
Step 1.
Response:
Please enter volume number:
13. At the RDLDFT display prompt, enter 3 for the volume number for SM Text.
Response:
What tape density is to be used?
Please enter the number ’8’ for low density or
the number ’0’ for high density:
14. At the RDLDFT display prompt, type and enter: 8 for the low tape density
identifier.
15. Once the tape density identifier has been selected, the following statement will
be displayed. Observe the statement, then continue with next step.
RDLDFT: SM TEXT tape sequence chosen for /dev/vtoc1 on /dev/mtxx
RDLDFT: Please mount the first backup tape on the tape drive
and insure that the ONLINE button is ON.
Please enter ’go’ after the tape is mounted:
Note: If this statement is not received within a few seconds, monitor ROP for
REPT FMGR UMOUNT FAILED output message and seek technical assistance
to identify process that is blocking UNMOUNT of SM text file system.
16. Make sure the switching module text tape is mounted, ensure that the tape drive
ONLINE button is ON, and then type and enter: : go
Note: As the tape is being loaded to disk, a tape load forward progressing dot
will appear on the terminal approximately every 30 seconds. Once the tape load
has completed, the following message will be printed.
Response: RDLDFT COMPLETED
RCV MENU RDLDFT COMPLETED
17. Was the RDLDFT COMPLETED message received?
If YES, switching module text has been loaded. Continue with the next step.
If NO, seek technical assistance.
18. Was rdldft invoked from the MCC?
If YES, exit from UNIX shell, type and enter: q and exit from the MCC Page 194,
type and enter: q
235-200-150
January 2003
SYSTEM RECOVERY
Procedure 7.2.2
Issue 3.00 Page 7.2.2-3