Perform this command even if the MCC Page 1800,x does not indicate forces are
there. There can be two different responses:
Response: ORD CPI x CMD CLR COMPLETED
OR
ORD CPI x CMD CLR NOT COMPLETED
UNIT RESULT x STATUS UNKNOWN
Where: x = The switching module number.
7. At the MCC Page 1800,x, type and enter: 705,UCL to allow the sanity timer.
Perform this command even if the MCC display page 1800,X does not indicate
the sanity timer has been inhibited. There can be two different responses to this
command.
Response: ORD CPI x CMD ALW COMPLETED
OR
ORD CPI x CMD ALW NOT COMPLETED
UNIT RESULT
x STATUS UNKNOWN
Where: x = The switching module number.
8. On the MCC Page 111/112, is the communication link to the switching module
broken?
If YES, continue with Step 9.
If NO, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
9. Halt the Administrative Workstation by executing Procedure 4.2.
10. Restore the Administrative Workstation by executing Procedure 4.3.
11. Restore MHDs 1 and 3 by poking 301 and 303 on the MCC 111/112 page.
12. On the MCC Page 111/112, is the communication link to the switching module
broken?
Warning: Steps 13-16 will stop all call processing and will drop all
stable calls! Do you wish to proceed?
13. Power down MCTSI 0 using only the OFF button located on MCTSI 0s Control
and Display Pack. DO NOT USE the MOR SWITCH.
14. At MCTSI 0 control and display pack, power up MCTSI 0.
15. Power down MCTSI 1 using only the OFF button located on MCTSI 1s Control
and Display Pack. DO NOT USE the MOR SWITCH.
16. At MCTSI 1 control and display pack, power up MCTSI 1.
17. On the MCC Page 111/112, is the communication link to the switching module no
longer broken?
If YES, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, seek technical assistance.
SYSTEM RECOVERY
Procedure 7.3
235-200-150
June 2004
Page 7.3-2 Issue 3.00J