(a) At DRM MCC, type and enter:
SET:RCACCESS,TTY="xxxx",ACCESS=a;
Where: a = Value obtained from the 235-600-700, Input Messages
Manual
xxxx = TTY name from TTY NAMES list in Step 3b (for
example, if growing VTTY12, xxxx = ttym)
(b) Check the access code, type and enter: OP:RCACCESS,TTY="xxxx"
Where: xxxx = TTY name from TTY NAMES list in Step 3b (for
example, if growing VTTY12, xxxx = ttym)
Response: The access code will be returned in hexadecimal.
7. Backup primary disk.
It is recommended that Primary Disk Backup be performed and a shelf copy of
the disks made.
8. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
GROWTH AND DEGROWTH
Procedure 8.1
235-200-150
January 2003
Page 8.1-4 Issue 3.00