V42/MNP/Buffer:
V42bic Compress = Disable
MNP5 Compress = Disable
Flw Cntl of DTE = XON/XOFF
Flw Cntl 0f Modem
= XON/XOFF
Security:
IMPORTANT: To prevent unauthorized access to the DRM’s MCC, set per local
guidelines.
17. If Modem B is a Paradyne 3810 modem, set the modem options on Modem B to
the same values as Modem A with the exception of the "DTE Dialer Type" field in
the "DTE_Dialer" submenu. For Modem B, "DTE Dialer Type" should be set to
Enable. If Modem B is not a Paradyne 3810 modem, follow the user manual
provided with the modem to provision it so that its communication parameters
(primarily the baud rate, parity, stop bits, and data bits) match that of Modem A.
18. Follow the user manual provided with the dial-up MCC terminal or terminal
emulator software package to set the communication parameters on the dial-up
MCC terminal to match those of the modems (for example, 9600 baud, 7 data
bits, 1 stop bit, Even parity).
19. Power up the AW units and dial-up MCC hardware in the following order:
For a Netra t 1120 or Netra 20 workstation:
1. MCC terminal
2. Modem A (Paradyne 3810)
3. Netra t 1120 and Netra 20 workstation. See "Restore Power to
Administrative Workstation (Netra t 1120 and Netra 20)", Procedure 4.8.
For a Netra 240 workstation:
1. MCC terminal
2. Modem A (Paradyne 3810)
3. Netra 240 workstation and external tape device. See "Restore Power to
Administrative Workstation Units (Netra 240)", Procedure 4.10.
20. Verify that the local MCC terminal is functional.
21. Verify that the dial-up MCC can be accessed.
a. Power up the dial-up MCC terminal and Modem B.
b. If the security options have not been set up on Modem A, type and enter:
ATDTxxxyyyy at the dial-up MCC terminal.
where xxxyyyy = the phone number of the analog line connected to Modem
A.
If the security options are set up on Modem A to require a password for
connection, type and enter: ATDTxxxyyyyWaaaaaaaa#
where: xxxyyyy = the phone number of the analog line to Modem A, and
aaaaaaaa = the 8 digit numeric password.
235-200-150
October 2005
GROWTH AND DEGROWTH
Procedure 8.5
Issue 3.00B Page 8.5-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent 5ESS DRM and is the answer not in the manual?

Lucent 5ESS DRM Specifications

General IconGeneral
BrandLucent
Model5ESS DRM
CategoryControl Unit
LanguageEnglish