A2.2.2 PRM:EE 60XX-B
A2.2.2.1 PRM Format
PRM_a EEbc 60de fggg ijkk hh hh hh
A2.2.2.2 PRM Source
Application Integrity Monitor (AIM).
A2.2.2.3 Function
UNIX RTR operating system application process initialization progress.
A2.2.2.4 PRM Expansion
a = Active control unit (CU):
0––CU0
1––CU1
E = Informational PRM.
E = Application software generated this PRM.
b = Level of most recent UNIX RTR operating system
initialization:
0 –– No initialization or D0 initialization.
1 –– D1 initialization.
2 –– D2 initialization.
3 –– D3 initialization.
4 –– D4 initialization.
These initializations are explained in 235-105-250, 5ESS
Switch System Recovery Manual.
c = Application initialization level within the UNIX RTR
Operating System initialization specified in field ’d’.
60 = Application function = DRM general initialization progress.
d = Administrative Module (AM) Software initialization level:
0 –– S0 (no AW SW initialization).
2 –– S2 (D1 = single process purge (SPP)) on all UNIX
RTR operating system application processes).
4 –– S4 (CI initialization).
5 –– S5 (application full process init (FPI)).
6 –– S6 (AM SW init w/o clearing phase protected data.)
7 –– S7 (AM SW init with phase protected data cleared.)
e = Not significant for DRM.
f = Not significant for DRM.
ggg = UNIX RTR operating system application process utility ID:
017 –– First in-first out (FIFO) driver (FDA).
0C0 –– Input/output driver (IODRV).
0C2 –– Scan and signal distributor administration (SCSD).
0CC –– RTR Data Link Driver for DRM
235-200-150
January 2003
APPENDIX 2
PROCESSOR RECOVERY MESSAGES
Issue 3.00 Page A2-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent 5ESS DRM and is the answer not in the manual?

Lucent 5ESS DRM Specifications

General IconGeneral
BrandLucent
Model5ESS DRM
CategoryControl Unit
LanguageEnglish