4. Execute the Sun Microsystems diagnostic of the newly installed SAI card. At the
# prompt, enter the following command. The response should be as shown here.
The diagnostic test takes approximately 15 seconds to complete.
/opt/SUNWvts/bin/saiptest -v -f -o dev=saip1,M=Internal,sp=b
Response:
"saiptest: Started."
.3 97/01/30 SMI"
"Baud rate = 9600, character size = 8, stop bit = 1,
parity = none, control flow = rtscts"
"data pattern = 0xaaaaaaaa"
"Internal Test"
"Testing device /dev/sad/saip1"
"Testing device /dev/term/b000"
"Testing device /dev/term/b001"
"Testing device /dev/term/b002"
"Testing device /dev/term/b003"
"Testing device /dev/term/b004"
"Testing device /dev/term/b005"
"Testing device /dev/term/b006"
"Testing device /dev/term/b007"
"End saiptest test"
"saiptest: Stopped successfully"
5. Did all of the Sun SAI/P diagnostics complete successfully?
If YES, continue with next step.
If NO, seek technical assistance.
6. Switch over to the MCC page of the AW by holding down the Ctrl key and
pressing Enter (not Return) on the MCC. Wait for the MCC display to appear.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
APPENDIX 3
ADMINISTRATIVE WORKSTATION (AW) SERIAL
ASYNCHRONOUS INTERFACE (SunSAI/P) BOARD GROWTH
235-200-150
January 2003
Page A3-6 Issue 3.00