A5.16 Configure the DRM Network qfe0 Port
A5.16.1 Introduction
Use this procedure to change the DRM AW qfe0 Port configuration and the DRM
Network settings on the DRM AW.
This procedure is performed whenever DRM Network configuration settings need to be
changed.
A5.16.2 Required Information
Before beginning this procedure, you must have the new DRM Network configuration
information, and know which DRM Network parameters are going to be updated.
Note: Changes to the DRM Network Configuration may require coordinated changes
on other components of the DRM Network (ASM, DRM Gateway/Router). Failure to
make the necessary coordinated changes could result in loss of communication over
the DRM Network.
A5.16.3 Procedure
1. Verify the MCC terminal is powered on and is properly connected to the
SUN
3
workstation.
2. If an MCC page is displayed, switch to the UNIX ® console of the AW by holding
down the Ctrl key and pressing Enter (not Return).
3. At the login prompt, log in as awadmin.
4. From the Administrative Workstation Main Menu, select "Configure DRM
Network qfe0 Port".
Response: Configure DRM Network qfe0 Port Sub-menu
Warning: These menu items apply to DRM Workstation configuration
procedures.
1) Configure DRM qfe0 Port Name and IP Address
2) Configure ASM Name and IP Address
3) Configure DRM Network Number and Subnet Mask
4) Configure DRM Gateway/Router IP Address
5) Return to the main menu
Select task by number (1-5):
5. From the Configure DRM Network qfe0 Port Sub-menu, select the appropriate
task to update the DRM Network configuration with the new configuration
values.
Response: The user will be prompted to enter the new configuration information,
or if the user wants to use the default values for this configuration.
6. After entering the new values, press Return to get back to the Configure DRM
Network qfe0 Port Sub-menu.
7. If performing other tasks from the Configure DRM Network qfe0 Port
Sub-menu, repeat steps 5 and 6. If the user has completed all necessary updates,
continue with step 8.
3. Registered trademark of Sun Microsystems, Inc.
APPENDIX 5
5ESS Switch DRM Administrative Workstation
NETRA
t 1120
to
NETRA
20 WITH SOLARIS 8 OS CONVERSION PROCESS
GUIDELINES
235-200-150
May 2003
Page A5-10 Issue 3.00