215620 210 Revision A
Figure 5.206: Couplers – Auger/Rotary Disc/Draper-
Ready Configuration
3. Ensure that hose (A) is disconnected from windrower
receptacle (B) and placed in storage cup (C) on the
multicoupler.
Figure 5.207: Header Hydraulic Fittings
4. Connect the hydraulic fittings to the hydraulic hoses as
follows:
NOTE:
The two quick couplers and two elbow fittings are supplied
in the Quick Coupler kit (MD #B6277).
a. Attach 90° elbow fitting (A) and 1 in. female coupler
fitting (B) to disc pressure hose (C).
b. Attach 90° elbow fitting (A) and 1 in. male coupler
fitting (D) to disc return hose (E).
ATTACHING A HEADER TO THE WINDROWER