Page #249 background imageLoading...
Page #249 background image
IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
6-27
oFC01
A1-A3
AO-A3
DI-A3
DO-A3
S4I
S4IO
Option connection error
at drive port CN5-C.
Option at drive port
CN5-C was changed
during run.
Turn off the power and
check the connectors
between the drive and
the option.
oFC02
A1-A3
AO-A3
DI-A3
DO-A3
S4I
S4IO
Option Fault (CN5-C).
Two of the same option
cards are connected
simultaneously.
AI-A3: AI-A3 option
connected to CN5-B
port while another input
option was connected
to CN5-A port.
DI-A3: DI-A3 option
connected to CN5-B
port while another input
option was connected
to CN5-A port.
AO-A3/DO-A3:
Duplicate type of
option card is
connected to drive
ports CN5-A, CN5-B,
and CN5-C.
AI-A3: Only one of the
options, AI-A3, DI-A3,
or SI-xx can be
connected to the drive
at the same time.
DI-A3: Only one of the
options, AI-A3, DI-A3,
or SI-xx can be
connected to the drive
at the same time.
AO-A3/DO-A3: Use
only compatible
options.
oFC03
to
oFC11
A1-A3
AO-A3
DI-A3
DO-A3
S4I
S4IO
Option Card Fault at
Option Port CN5-C.
Option card or
hardware is damaged.
Cycle power to the
drive
If the problem
continues, replace the
control board or the
entire drive. Contact
Magnetek for
instructions on
replacing the control
board.
oFC12
to
oFC17
A1-A3
AO-A3
DI-A3
DO-A3
S4I
S4IO
Option Card Fault at
Option Port CN5-C.
Option card or
hardware is damaged.
Cycle power to the
drive
If the problem
continues, replace the
control board or the
entire drive. Contact
Magnetek for
instructions on
replacing the control
board.
oPE05
A1-A3
DI-A3
S4I
S4IO
Run command/frequency
reference source
selection error.
Frequency reference is
assigned to an option
(B03-01 = 3), but an
option is not
connected.
Reconnect the option
to the drive.
oPE06
-- Control Method Selection
Error
A control mode has
been selected that
requires a PG option
card to be installed, but
no PG encoder is
installed (A01-02 = 1 or
3).
Connect to a PG option
card.
Correct the value set to
A01-02.
Error Card
Fault or Indicator
Name/Description Cause Possible Solution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek Impulse G+ series 4 and is the answer not in the manual?