IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
4-11
Table 4-5: X-Press Programming I/O Quick Reference
A01-04 =0123456
Terminal S1 FWD FWD FWD FWD FWD FWD FWD
Terminal S2 REV REV REV REV REV REV REV
Terminal S3 Step 2 Step 2 Step 2 Accel Hold -- --
Terminal S4 -- Step 3 Step 3 -- Accel -- --
Terminal S5----Step 4--------
Terminal S6----Step 5--------
Terminal S7 -- -- -- -- -- -- --
Terminal S8 -- -- -- -- -- -- --
Terminal A1 -- -- -- -- -- FREF FREF
Terminal M0/M1 Brake Brake Brake Brake Brake Brake Brake
Terminal M2/M3 Brake (NLB), otherwise not used
Terminal M5/M6 Fault Annunciate (NLB), otherwise not used
WARNING
When changing A01-03 or A01-04, MFDI, MFDO, and speed reference parameters will be
overwritten by X-Press Programming
TM
(Table 4-6, 4-7, or 4-8 on pages 4-12, 4-13, and 4-14).
All parameter settings must be verified for proper operation.