MAN Diesel 4.10
Page 2 of 2
MAN Diesel
198 42 101.5MAN B&W K98MC/MC-C/ME/ME-C, S90MC-C/ME-C, K90MC-C/ME/ME-C,
S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46ME-B, S40ME-B, S35ME-B
Fig. 4.10.02: List of capacities for L28/32H, IMO Tier I.
L28/32H GenSet Data
Cyl. 5 6 7 8 9
Max. continuous rating at
720/
750 RPM
kW
1,050/
1,100
1,260/
1,320
1,470/
1,540
1,680/
1,760
1,890/
1,980
Engine-driven Pumps:
Fuel oil feed pump (5.5-7.5 bar) m
3
/h 1.4 1.4 1.4 1.4 1.4
L.T. cooling water pump (1-2.5 bar) m
3
/h 45 60 75 75 75
H.T. cooling water pump (1-2.5 bar) m
3
/h 45 45 60 60 60
Lub. oil main pump (3-5 bar) m
3
/h 23 23 31 31 31
Separate Pumps:
Diesel oil Pump (4 bar at fuel oil inlet A1) m³/h 0.73/0.77 0.88/0.92 1.02/1.08 1.17/1.23 1.32/1.38
Fuel oil supply pump *** (4 bar discharge pressure) m
3
/h 0.36/0.38 0.43/0.45 0.50/0.53 0.57/0.60 0.64/0.68
Fuel oil circulating pump (8 bar at fuel oil inlet A1) m³/h 0.74/0.78 0.89/0.93 1.04/1.09 1.18/1.25 1.33/1.40
L.T. cooling water pump* (1-2.5 bar) m
3
/h 45 54 65 77 89
L.T. cooling water pump** (1-2.5 bar) m
3
/h 65 73 95 105 115
H.T. cooling water pump (1-2.5 bar) m
3
/h 37 45 50 55 60
Lub. oil stand-by pump (3-5 bar) m
3
/h 22 23 25 27 28
Cooling Capacities:
Lubricating Oil:
Heat dissipation kW 105 127 149 172 194
L.T. cooling water quantity* m
3
/h 7.8 9.4 11.0 12.7 14.4
SW L.T. cooling water quantity** m
3
/h 28 28 40 40 40
Lub. oil temp. inlet cooler °C 67 67 67 67 67
L.T. cooling water temp. inlet cooler °C 36 36 36 36 36
Charge Air:
Heat dissipation kW 393 467 541 614 687
L.T. cooling water quantity m
3
/h 37 45 55 65 75
L.T. cooling water inlet cooler °C 36 36 36 36 36
Jacket Cooling:
Heat dissipation kW 264 320 375 432 489
H.T. cooling water quantity m
3
/h 37 45 50 55 60
H.T. cooling water temp. inlet cooler °C 77 77 77 77 77
Gas Data:
Exhaust gas flow kg/h 9,260 11,110 12,970 14,820 16,670
Exhaust gas temp. °C 305 305 305 305 305
Max. allowable back. press. bar 0.025 0.025 0.025 0.025 0.025
Air consumption kg/s 2.51 3.02 3.52 4.02 4.53
Starting Air System:
Air consumption per start Nm
3
2.5 2.5 2.5 2.5 2.5
Heat Radiation:
Engine kW 26 32 38 44 50
Generator kW (See separat data from generator maker)
The stated heat dissipation, capacities of gas and engine-driven pumps are given at 720 RPM. Heat dissipation gas and pump capaci-
ties at 750 RPM are 4% higher than stated. If L.T. cooling are sea water, the L.T. inlet is 32° C instead of 36°C.
Based on tropical conditions, except for exhaust flow and air consumption which are based on ISO conditions.
* Only valid for engines equipped with internal basic cooling water system nos. 1 and 2.
** Only valid for engines equipped with combined coolers, internal basic cooling water system no. 3.
*** To compensate for built on pumps, ambient condition, calorific value and adequate circulations flow. The ISO fuel oil consumption
is multiplied by 1.45.