MAN B&W 6.03
Page 1 of 5
MAN Diesel
MAN B&W S50Mc-c8-TII 198 70 90-5.0
List of Capacities for 5S50MC-C8-TII at NMCR - IMO NO
x
Tier II compliance
Seawater cooling Central cooling
Conventional TC High eff. TC Conventional TC High eff. TC
-
-
-
1 x TCA66-21
1 x A175-L32
1 x MET53MA
-
-
-
1 x TCA66-21
1 x A175-L32
1 x MET53MA
Pumps
Fuel oil circulation m³/h N.A. N.A. N.A. 4.8 4.8 4.8 N.A. N.A. N.A. 4.8 4.8 4.8
Fuel oil supply m³/h N.A. N.A. N.A. 2.1 2.1 2.1 N.A. N.A. N.A. 2.1 2.1 2.1
Jacket cooling m³/h N.A. N.A. N.A. 70.0 70.0 70.0 N.A. N.A. N.A. 70.0 70.0 70.0
Seawater cooling * m³/h N.A. N.A. N.A. 270.0 270.0 270.0 N.A. N.A. N.A. 265.0 265.0 260.0
Main lubrication oil * m³/h N.A. N.A. N.A. 170.0 170.0 170.0 N.A. N.A. N.A. 170.0 170.0 170.0
Central cooling * m³/h - - - - - - - - - 210 210 205
Scavenge air cooler(s)
Heat diss. app. kW N.A. N.A. N.A. 3,470 3,470 3,470 N.A. N.A. N.A. 3,450 3,450 3,450
Central water flow m³/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 118 118 118
Seawater flow m³/h N.A. N.A. N.A. 179 179 179 N.A. N.A. N.A. - - -
Lubricating oil cooler
Heat diss. app. * kW N.A. N.A. N.A. 680 680 650 N.A. N.A. N.A. 680 680 650
Lube oil flow * m³/h N.A. N.A. N.A. 170.0 170.0 170.0 N.A. N.A. N.A. 170.0 170.0 170.0
Central water flow m³/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 92 92 87
Seawater flow m³/h N.A. N.A. N.A. 91 91 91 N.A. N.A. N.A. - - -
Jacket water cooler
Heat diss. app. kW N.A. N.A. N.A. 1,210 1,210 1,210 N.A. N.A. N.A. 1,210 1,210 1,210
Jacket water flow m³/h N.A. N.A. N.A. 70 70 70 N.A. N.A. N.A. 70 70 70
Central water flow m³/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 92 92 87
Seawater flow m³/h N.A. N.A. N.A. 91 91 91 N.A. N.A. N.A. - - -
Central cooler
Heat diss. app. * kW N.A. N.A. N.A. - - - N.A. N.A. N.A. 5,340 5,340 5,310
Central water flow m³/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 210 210 205
Seawater flow m³/h N.A. N.A. N.A. - - - N.A. N.A. N.A. 265 265 260
Starting air system, 30.0 bar g, 12 starts. Fixed pitch propeller - reversible engine
Receiver volume N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5 N.A. N.A. N.A. 2 x 4.5 2 x 4.5 2 x 4.5
Compressor cap. N.A. N.A. N.A. 270 270 270 N.A. N.A. N.A. 270 270 270
Starting air system, 30.0 bar g, 6 starts. Controllable pitch propeller - non-reversible engine
Receiver volume N.A. N.A. N.A. 2 x 2.5 2 x 2.5 2 x 2.5 N.A. N.A. N.A. 2 x 2.5 2 x 2.5 2 x 2.5
Compressor cap. N.A. N.A. N.A. 150 150 150 N.A. N.A. N.A. 150 150 150
Other values
Fuel oil heater kW N.A. N.A. N.A. 125 125 125 N.A. N.A. N.A. 125 125 125
Exh. gas temp. °C N.A. N.A. N.A. 245 245 245 N.A. N.A. N.A. 245 245 245
Exh. gas amount kg/h N.A. N.A. N.A. 74,500 74,500 74,500 N.A. N.A. N.A. 74,500 74,500 74,500
Air consumption kg/h N.A. N.A. N.A. 20.3 20.3 20.3 N.A. N.A. N.A. 20.3 20.3 20.3
* For main engine arrangements with built-on power take-off (PTO) of a MAN Diesel recommended type and/or torsional vibration
damper the engine's capacities must be increased by those stated for the actual system
For List of Capacities for derated engines and performance data at part load please visit http://www.manbw.dk/ceas/erd/
Table 6.03.01e: Capacities for seawater and central systems as well as conventional and high efficiency turbochargers stated at NMCR