Table 5.06.04 indicates the maximum permis-
sible forces (F, F2 and F3) and moments (M and
M3), on the exhaust gas outlet ange of the turbo-
charger(s). Reference is made to Fig. 5.06.03.
Table 15.06.04: The max. permissible forces and moments on the turbocharger’s gas outlet anges
Turbocharger M1 M3 F1 F2 F3
Make Type Nm Nm N N N
MAN Diesel
TCA55 3,400 6,900 9,00 9,00 4,500
TCA66 3,700 7,500 9,900 9,900 4,900
TCA77 4,00 8,200 0,900 0,900 5,400
NA48 3,600 2,400 6,000 6,000 2,400
NA57 4,300 3,000 7,000 7,000 3,000
NA70 5,300 3,500 8,800 8,800 3,500
ABB
TPL73 5,500 5,500 9,500 9,000 9,000
TPL77 7,700 7,700 ,500 0,000 0,000
TPL80 ,000 ,000 5,000 3,000 3,000
MHI
MET53 4,900 2,500 7,300 2,600 2,300
MET66 6,800 3,400 9,300 3,200 3,000
MET7
7,000 3,500 9,600 3,300 3,00
078 38 48-6.2.0
-
-
&
&&
&
-!.æ$IESEL
-
&
&
-ITSUBISHI
-
- -
&&
&
!""æ40,
Fig. 15.06.03: Forces and moments on the turbochargers’ exhaust gas outlet ange

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Man B&W S50MC-C8-TII and is the answer not in the manual?

Man B&W S50MC-C8-TII Specifications

General IconGeneral
BrandMan
ModelB&W S50MC-C8-TII
CategoryEngine
LanguageEnglish

Related product manuals