MAN B&W 16.01
Page 5 of 11
MAN Diesel
MAN B&W MC/MC-C engines 198 79 08-1.0
Starting Air System
178 58 11.5-0
Fig. 16.01.03: Starting air system, with slow turning, option: 4 50 140
Starting valve
Starting air
distributor
Service / Blocked
Main starting valve
A
Ø16X2
Ø16X2
Slow turning
valve
ZV 1114 C
ZS 1116 C
ZS 1117 C
ZS 1111 C
ZS 1112 C
Engine control
room console
78
Slow turning
28
Additional components for slow turning are the slow turning valve in bypass and position nos. 28 and 78
The item No. refers to ‘Guidance values ‘automation’
The letter refers to list of ‘Counterflanges’
The piping is delivered with and fitted onto the engine
Pos. Qty. Description
28 1 3/4-way solenoid valve
78 1 Switch, yard’s supply