Parametrization of emergency drive
131
Read this manual carefully before starting any work!
This is particularly applicable to the chapter “General Safety Instructions”
and the respective safety instructions in the chapters.
Error message: “Emergency Drive Error/Faulty ID”
In the display on which the error message is
displayed, an operator's stand is parametrized
with an ID that is already present in the system
network.
Possible causes/procedure:
S Re-parametrize operator's stand in the display
“Unregister stand”, then configure again.
Example of an error message that always occurs
during parametrization:
During system parametrization, four operator's
stands were set but no other parametrization yet
undertaken. The following error message is output:
Operator's stands with the ID 1, 2 is not found.
Then configure the operator's stands one after the
other in the displays provided for emergency
operation.