Parametrization of emergency drive
130
Read this manual carefully before starting any work!
This is particularly applicable to the chapter “General Safety Instructions”
and the respective safety instructions in the chapters.
15.2 Possible error messages
Error message: “Missing Emergency Drive stands”
The operator's stand with the ID 1 is not found in
the system configuration shown on the right.
Possible causes/procedure:
S The display with the parametrized operator's
stand ID 1 is switched off → Switch on the
display
S More operator's stands have been
parametrized than are available →
Re-parametrize the system.
Error message: “Unconfigured Emergency Drive stands”
An operator's stand with the ID 1 is found in the
system configuration shown on the right, although
this was not parametrized.
Possible causes/procedure:
S Add operator's stand → Re-parametrize the
system.
S Search for the display with the parametrized
operator's stand ID 1 → Remove the operator's
stand there.
See “Display configuration” - set the operator's
stand in the display, page 129
Error message: “Defective Emergency Drive stands”
The operator's stand with the ID 1 is detected as
defective in the system configuration shown on the
right.
Possible causes/procedure:
S Display off / on
S Re-parametrize the operator's stand with the
ID 1 → “Unregister stand”, then configure again.