Manitowoc Published 08-06-19, Control # 237-09_v1 3-43
MLC165-1 OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
drum handle toward center to slow down the load. Then
fully apply the brake to stop the load. Release the
drum handle to center. Maintain foot pedal pressure
to hold the load in place.
6. If a load will be suspended for any length of time, latch
down the brake pedal and turn on the drum park switch.
7. To turn off free fall for the desired drum:
a. Latch down the desired brake pedal.
b. Use the free fall enable/disable key switch to select
the free fall drum to be turn off. The amber indicator
light will turn off.
c. Move the corresponding free fall selector valve
handle to the off position (Figure 3-12 on page 3-
42).