74 Matrox Display Wall – User Guide
Appendix A – Firewall requirements
The following are the firewall requirements for your display wall system and for a network when using
Network API, MuraControl, or a Mura IPX Series product.
Network API and MuraControl
The following are the firewall requirements when using Network API or MuraControl through the
network to configure your display wall controller.
Display wall system
The following are the requirements for a network firewall present on a network with a Mura IPX
Series product.
Network ports Type Inbound Outbound Functionality
23 TCP 99Telnet: Telnet commands
46272 TCP 99HTTPS: Authentication
Network ports Type Inbound Outbound Functionality
69 UDP 9 DHCP: DHCP client
123 UDP 99NTP: Network Time Protocol
161 UDP 99
SNMP: Network management – public
community string
1500 UDP 99MPEG-2 TS: Streaming (configurable)
1500 UDP 99SRT: Streaming (configurable)
1900 UDP 99
UPnP: Microsoft SSDP for discovery of
UPnP devices
554, 8554
*
* Default ports. Actual ports may vary.
TCP 99RTSP: Streaming (configurable)
16000+ UDP 99
RTP/RTCP: Audio and video streams
and control