72 Matrox Display Wall – User Guide
Environmental
Mean Time Before Failure (MTBF)
Temperature, operational
Mura MPX Series: 0 to 40 ºC (32 to 104 ºF)
Mura IPX Series: 0 to 45 ºC (32 to 113 ºF)
C-Series: 5 to 55 ºC (41 to 131 ºF) (near board ambient)
Temperature, non-operational
storage and transportation
Mura MPX Series and Mura IPX Series: -40 to 65 ºC (-40 to
149 ºF)
C-Series: -40 to 70ºC (-40 to 158 ºF)
Humidity, operational (indoor) 20 to 80% (non-condensing)
Humidity, non-operational storage
and transportation
10% to 95% (non-condensing)
Atmospheric pressure, operational
650hPa (3,580 meters / 11,745 feet)
to 1013hPa (0 meters / 0 feet)
Atmospheric pressure,
non-operational and transportation
192hPa (12,000 meters / 39,370 feet)
to 1020hPa (-50 meters / -164 feet)
MTBF
*
MURAIPXI-E4SHF 74.44 years or 652,499 hours
MURAIPXI-E4SF 7.21 years or 63,217 hours
MURAIPXI-E2MHF 75.28 years or 659,887 hours
MURAIPXI-E2MF 7.22 years or 63,286 hours
MURAIPXI-D2MHF 75.28 years or 659,887 hours
MURAIPXI-D2MF 7.22 years or 63,286 hours
MURAIPXO-D4LHF 72.63 years or 636,707 hours
MURAIPXO-D4LF 6.56 years or 57,469 hours
MURAIPXI-E4JHF 76.51 years or 670,700 hours
MURAIPXI-E4JF 7.23 years or 63,384 hours
MURAIPXI-D4JHF 76.51 years or 670,700 hours
MURAIPXI-D4JF 7.23 years or 63,384 hours
Mura MPX-4/4
71.11 years or 622,944 hours
Mura MPX-4/2
75.41 years or 660,615 hours
Mura MPX-4/0
90.03 years or 788,631 hours