EasyManuals Logo

Meggitt vibro-meter VM600 User Manual

Meggitt vibro-meter VM600
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Document reference MAMPS-HW/E HARDWARE MANUAL
Edition 18 - March 2022 VM600 machinery protection system (MPS)
xi
Part II: Installing VM600 MPS hardware and using the system
Part III: Maintenance and technical support
Part IV: Appendices
Chapter 8
Installation – Provides information on installing the cards and power supplies in the VM600
MPS rack.
Chapter 9
Configuration of MPC4 / IOC4T cards – Describes the connectors on the IOC4T card.
Includes typical connection diagrams for measurement signal sensors (for example,
accelerometers, proximity probes) and speed signal sensors. Contains information on
attributing specific alarm signals to specific relays on RLC16 cards using the Open
Collector Bus and the Raw Bus.
Chapter 10
Configuration of AMC8 / IOC8T cards – Describes the connectors on the IOC8T card.
Includes typical connection diagrams for thermocouples, RTD devices as well as other
sensors providing a voltage-based or current-based signal. Contains information on
attributing specific alarm signals to specific relays on RLC16 cards using the Open
Collector Bus and the Raw Bus.
Chapter 11
Using the RLC16 card – Provides information on the screw terminal strips on these relay
cards.
Chapter 12
Using the IRC4 card – Provides information on the screw terminal strips on these relay
cards. Also contains information on attributing specific alarm signals to specific relays on
an IRC4 using the Open Collector and Raw buses.
Chapter 13
Configuration of CPUM / IOCN cards – Contains details on configuring jumpers on the two
cards, as well as information on connectors.
Chapter 14
Maintenance and troubleshooting – Contains some basic tips for fault-finding. Also
includes information on long-term storage of racks.
Chapter 15
End-of-life product disposal – Provides information and contact details concerning the
environmentally friendly disposal of electrical/electronic equipment at the end of its useful
life.
Chapter 16
Service and support – Provides contact details for technical queries and information
concerning the repair and return of equipment.
Appendix A: Environmental specifications – Contains general environmental specifications for the
entire machinery protection system viewed as a whole.
Appendix B: Data sheets – Includes data sheet information for all cards and other system components
used in the VM600 MPS. The data sheets provide full electrical and mechanical
specifications, ordering information and so on.
Appendix C: Definition of backplane connector pins – Contains pin definitions for connectors P1, P2, P3
and P4 for each slot in the ABE04x rack.
Appendix D: Abbreviations and symbols – Contains a list of abbreviations and measurement unit
symbols used in this document.
Energy product return procedure
Allows the user to indicate problems observed on a
card/module/system component, thus enabling our Customer
support department to repair the equipment as quickly as possible.
Energy customer feedback form
Allows the user to provide us with valuable feedback on our
documentation.

Table of Contents

Other manuals for Meggitt vibro-meter VM600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meggitt vibro-meter VM600 and is the answer not in the manual?

Meggitt vibro-meter VM600 Specifications

General IconGeneral
BrandMeggitt
Modelvibro-meter VM600
CategoryProtection Device
LanguageEnglish