POWER TRIM
Page 5B-16 90-855347R1 JANUARY 1999
Troubleshooting the “Up” Circuit
Battery Voltage Indicated:
Battery Voltage Indicated:
No Voltage Indicated:
No Voltage Indicated:
No Voltage Indicated:
No Voltage Indicated:
Connect Voltmeter red lead to
Point 5. If battery voltage is indi-
cated, trim switch is faulty. If no
battery voltage, check for loose
or corroded connection at Point
5 or open circuit in wire supply-
ing current to Point 5.
Relay Switch is defective.
There is an open circuit be-
tween Point 9 and positive (+)
battery terminal.
Connect Voltmeter red lead to
Point 6.
Connect Voltmeter red lead to
Point 9.
Connect Voltmeter red lead to
Point 7 and black lead to ground.
Depress “Up” trim button. If bat-
tery voltage is indicated, wire is
open between Points 7 and 8.
Connect Voltmeter red lead to
Point 8 and black lead to ground.
Depress the “Up” trim button.
Depress “Up” trim button.
Pump motor wiring is defec-
tive.
Pump motor is defective.
Check for loose or corroded
connections.
Check wires for open.
Battery Voltage Indicated:
Test DOWN relay.
Refer to page 5B-13 for relay
test procedure.
Relay good:

Table of Contents

Other manuals for Mercury Optimax 115

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury Optimax 115 and is the answer not in the manual?

Mercury Optimax 115 Specifications

General IconGeneral
Fuel Induction System2-stage Direct Fuel Injection (DFI)
Alternator Amp60 amp / 756 watt
SteeringRemote
Cylinders3
StartingElectric
Displacement1.5 L
Bore x Stroke89 x 76 mm
Shaft Length20" (508 mm)
Horsepower115 HP

Related product manuals